Back to NK
Technologies Main Selection Page |
AC and DC Current Switches |
AS1 Series, Single-Range AC Current Switch |
AS1 DODC
Series, Current Switch with Dual Output |
AS3 Series, Multi-Range AC Current Operated Switches |
ASM Series,
Self-Calibrating AC Current Switches |
ASX Series, AC Current Switches with Time Delay |
ASXP Series,
Powered AC Current Switches with Time Delay |
AS0 Series, Low Range AC Current Operated Switches |
DS3 Series, DC
Current Operated Switches |
AC and DC Current
Transducers |
AT Series, AC Current Transducers, Average Responding |
ATR Series, AC
Current Transducers, True RMS |
AT/ATR 3 & 4 Series, High Current AC Transducers |
ATP Series, Powered
AC Current Transducers |
ATP/ATPR 3 & 4 Series, Powered AC Current Transducers, True
RMS |
DT Series, DC Current
Transducers |
Ground Fault / Earth Leakage
Sensors |
AG Series, Ground Fault/Earth Leakage Sensors - Solid-State
Relay Output |
AG Series, Ground
Fault/Earth Leakage Sensors - Mechanical Relay Output |
AGL Series, Large Aperture Ground Fault
Sensors |
|
ATP Series, Powered AC Current Transducers |
|
ATP Series Powered Current Transducers sense currents from 0200A and provide a proportional analog VDC or mA output. Powered by 120VAC or 24VAC/VDC, the ATP Series eliminates the need for costly power supplies or voltage rectifiers inside the control panel. Designed for motor control applications with standard sinusoidal waveforms, the ATP features user-selectable input ranges, a choice of outputs and split-core or solidcore enclosures. |
|
Download Complete Specifications in .pdf Format |
Commercial and Industrial Motor Control Centers
- 120VAC power supply option allows for
powering off of readily available supplies; ideal for pumping,
water/wastewater, boiler and other industrial applications.
- Eliminates the need for 24VDC power supply
or AC rectifiers within the control panel; saves space, material and labor
associated with power supplies.
|
|
- Fast, Accurate RMS Measurement - Unique
‘average responding’ algorithm provides RMS output on pure sine wave
and constant speed loads, offering improved accuracy over two-piece
solutions.
- Jumper Selectable Input Ranges - Each unit
has multiple input range capability and can be used for a variety of
applications, reducing the need for separate models.
- Isolation Output -Output is magnetically
isolated from the input for enhanced safety and elimination of insertion
losses.
|
|
|
|
|
-005 Model |
-010 Model |
-420 Model |
Output Signal |
05VDC |
010VDC |
420mA |
Output Limit |
112% (5.6V) |
112% (11.2V) |
112% (22.4mA) |
Loading |
- 25KOhms min.: VDC Models
- 500Ohms max.: 4–20mA Models
|
Response Time |
100ms (1090% step change) |
Frequency Range |
40100 Hz standard. Special calibration for frequencies 100400Hz, consult factory. |
Accuracy |
- Solid-core: <0.5%
- Split-core: 1%
|
Power Supply |
120VAC or 24VAC/VDC, 2VA max |
Isolation Voltage |
UL listed to 1,270VAC (tested to 5KV) |
Input Ranges |
0200A Jumper-selectable |
Sensing Aperture |
- -FF Case: 0.55” (14mm) dia.
- -SP Case: 0.85” (21.6mm) sq.
|
Case |
UL94 V0 Flammability Rated |
Environmental |
5 to 122oF (-15 to 50oC) 095% RH, non-condensing |
. |
|
|
|
Ordering Information |
Download Complete Specifications in .pdf Format |
Solid-Core Models |
Model |
Description |
Output |
ATP0-420-120-FF |
02 & 05A Ranges, Front Term. |
420mA |
ATP0-010-120-FF |
02 & 05A Ranges, Front Term. |
010VDC |
ATP0-420-24U-FF |
02 & 05A Ranges, Front Term. |
420mA |
ATP0-010-24U-FF |
02 & 05A Ranges, Front Term. |
010VDC |
ATP1-420-120-FF |
010, 020, 050A Ranges, Front Term. |
420mA |
ATP1-010-120-FF |
010, 020, 050A Ranges, Front Term. |
010VDC |
ATP1-420-24U-FF |
010, 020, 050A Ranges, Front Term. |
420mA |
ATP1-010-24U-FF |
010, 020, 050A Ranges, Front Term. |
010VDC |
ATP2-010-120-FF |
0100, 0150, 0200A Ranges, Front Term. |
010VDC |
ATP2-420-24U-FF |
0100, 0150, 0200A Ranges, Front Term. |
420mA |
ATP2-010-24U-FF |
0100, 0150, 0200A Ranges, Front Term. |
010VDC |
ATP2-420-120-FF |
0100, 0150, 0200A Ranges, Front Term. |
420mA |
Split-Core Models |
Model |
Description |
Output |
ATP0-420-120-SP |
02 & 05A Ranges |
420mA |
ATP0-010-120-SP |
02 & 05A Ranges |
420mA |
ATP0-420-24U-SP |
02 & 05A Ranges |
420mA |
ATP0-010-24U-SP |
02 & 05A Ranges |
010VDC |
ATP1-420-120-SP |
010, 020, 050A Ranges |
420mA |
ATP1-010-120-SP |
010, 020, 050A Ranges |
420mA |
ATP1-420-24U-SP |
010, 020, 050A Ranges |
420mA |
ATP1-010-24U-SP |
010, 020, 050A Ranges |
010VDC |
ATP2-420-120-SP |
0100, 0150, 0200A Ranges |
420mA |
ATP2-010-120-SP |
0100, 0150, 0200A Ranges |
420mA |
ATP2-420-24U-SP |
0100, 0150, 0200A Ranges |
420mA |
ATP2-010-24U-SP |
0100, 0150, 0200A Ranges |
010VDC |
|
|