Back to NK
Technologies Main Selection Page |
AC and DC Current Switches |
AS1 Series, Single-Range AC Current Switch |
AS1 DODC
Series, Current Switch with Dual Output |
AS3 Series, Multi-Range AC Current Operated Switches |
ASM Series,
Self-Calibrating AC Current Switches |
ASX Series, AC Current Switches with Time Delay |
ASXP Series,
Powered AC Current Switches with Time Delay |
AS0 Series, Low Range AC Current Operated Switches |
DS3 Series, DC
Current Operated Switches |
AC and DC Current
Transducers |
AT Series, AC Current Transducers, Average Responding |
ATR Series, AC
Current Transducers, True RMS |
AT/ATR 3 & 4 Series, High Current AC Transducers |
ATP Series, Powered
AC Current Transducers |
ATP/ATPR 3 & 4 Series, Powered AC Current Transducers, True
RMS |
DT Series, DC Current
Transducers |
Ground Fault / Earth Leakage
Sensors |
AG Series, Ground Fault/Earth Leakage Sensors - Solid-State
Relay Output |
AG Series, Ground
Fault/Earth Leakage Sensors - Mechanical Relay Output |
AGL Series, Large Aperture Ground Fault
Sensors |
|
NK Technologies - AG Series, Ground Fault (Earth Leakage) Sensors with Solid-State Relay Output |
|
AG Series Ground Fault Sensors help protect people, products, and processes from damage by ground fault conditions by monitoring all current-carrying conductors in grounded single- and three-phase delta or wye systems.
Zero Sum Operating Principle: In threephase delta and wye systems, under normal conditions current in the hot leg of a two-wire load is equal in magnitude but opposite in sign to the current in the neutral leg. As a result, the electromagnetic fields surrounding these two conductors cancel, producing a zero sum current. As soon as current leaks to ground (fault condition) the two currents become imbalanced and a net magnetic field results. AG Series sensors monitor this field and trip alarm contacts when the leakage rises above setpoint. |
|
|
|
Download Complete Specifications in .pdf Format |
Personnel Protection (typically 5mA)
- Detects sensitive ground fault conditions,
which may be injurious to personnel and processes.
- Functions as sensor and alarm trigger when
part of an overall ground fault protection system.
|
Equipment Protection (typically 10mA or 30mA) For applications where personal protection is not the primary concern, higher setpoint capability helps eliminate nuiscance tripping while still providing adequate ground fault detection to protect machine electronics. |
Regulatory
Meets requirements as stipulated by governmental and industrial regulatory groups for ground fault sensing. |
|
AG Series with Solid-state Outputs offer the benefit of reliable, long-lasting solidstate switches. Sold-state design provides unlimited switch operating life, superior resistance to shock and vibration, zero offstate leakage, high switch speeds and high input-output isolation. Available in solidcore case with screw terminals. |
|
|
- Broad Range of Options to Match Application
Needs
- N.O./N.C. solid-state switch or
mechanical relay outputs.
- Normally energized or normally
de-energized contacts.
- Noise Immunity option for use in
EMI/RFI sensitive environments.
- Setpoint Options Maximize Ease-of-Use
- Field selectable 5mA, 10mA or 30mA
setpoints on the AG3 “Tri-set” model makes user adjustments fast,
sure and convenient.
- Single factory calibrated setpoints
available form 5mA to 950mA.
- Compatible with Standard Equipment
- Applicable on single- and three-phase
systems.
- ..Ideal for use with shunt trip
breakers.
- Magnetically isolated from monitored
circuit and control power.
- Agency Approved - UL, CE approved.
|
|
|
|
Setpoint Range |
Factory calibrated models (specify when ordering):
- AG1: 5–100mA (005–100)
- AG2: 80–950mA (080–950)
|
TR3 Tri-set models (field jumper select): AG3: 5, 10, or 30mA |
Output |
Solid-State Output Models |
Mechanical Output Models |
Isolated Dry Contact |
Mechanical Relay |
Output Rating |
- Solid-state AC Switch 1A @ 240VAC
- Solid-state DC Switch 0.15A @ 30VAC
|
- Auto Reset: SPDT Relay 1A @ 125VAC, 2A @
30VDC
- Latching: SPST Relay 1A @ 125VAC, 2A @
30VDC
|
Off State Leakage |
- <10 micro Amps (N.O.)
- <2.5mA (N.C.)
|
None |
Response Time |
- 200ms @ 5% above trip point
- 60ms @ 50% above trip point
15ms @ 500%
above trip point
|
Isolation Voltage |
5,000 VAC (tested) |
Frequency Range |
50400 Hz (monitored circuit) |
Noise Immunity Option |
N/A |
- EMI/RFI Shielding
- Power supply noise filtering
|
Power Supply |
- 120VAC (55–110% of nominal voltage)
- 24VAC/VDC (+/- 20%)
- Green LED = Power On indication
|
Loading |
2VA Max. |
Case |
UL94 V0 Flammability Rated |
Environmental |
-4 to 122°F (-20 to 50°C), 095% RH, non-condensing |
Listings |
UL 1053, Class 1 Recognized, CE |
|
|
|
Ordering Information |
Download Complete Specifications in .pdf Format |
Solid-State Relay Output Models |
Model |
Description |
Output |
Power Supply |
Notes |
AG1-NCAC-120-FS-SSS |
5100mA, SS Out., Nor. Ener. |
N.C. 1A@240VAC |
120VAC |
Special Order Items- SSS is the Setpoint. Indicate your desired setpoint 005 (5mA) through 100 (100mA) for the AG1 models and 005 (5mA) through 950 (950mA) for the AG2 models in the Special Shipping Instructions of your order. |
AG1-NCAC-24U-FS-SSS |
24VAC/DC |
AG1-NCAC-120-NF-SSS |
5100mA, SS Out., Nor. De-Ener. |
N.C. 1A@240VAC |
120VAC |
AG1-NCAC-24U-NF-SSS |
24VAC/DC |
AG1-NCDC-120-FS-SSS |
5100mA, SS Out., Nor. Ener. |
N.C. 0.15A@30VDC |
120VAC |
AG1-NCDC-24U-FS-SSS |
24VAC/DC |
AG1-NCDC-120-NF-SSS |
5100mA, SS Out., Nor. De-Ener. |
N.C. 0.15A@30VDC |
120VAC |
AG1-NCDC-24U-NF-SSS |
24VAC/DC |
AG1-NOAC-120-FS-SSS |
5100mA, SS Out., Nor. Ener. |
N.O. 1A@240VAC |
120VAC |
AG1-NOAC-24U-FS-SSS |
24VAC/DC |
AG1-NOAC-120-NF-SSS |
5100mA, SS Out., Nor. De-Ener. |
N.O. 1A@240VAC |
120VAC |
AG1-NOAC-24U-NF-SSS |
24VAC/DC |
AG1-NODC-120-FS-SSS |
5100mA, SS Out., Nor. Ener. |
N.O. 0.15A@30VDC |
120VAC |
AG1-NODC-24U-FS-SSS |
24VAC/DC |
AG1-NODC-120-NF-SSS |
5100mA, SS Out., Nor. De-Ener. |
N.O. 0.15A@30VDC |
120VAC |
AG1-NODC-24U-NF-SSS |
24VAC/DC |
AG2-NCAC-120-FS-SSS |
80950mA, SS Out., Nor. Ener. |
N.C. 1A@240VAC |
120VAC |
AG2-NCAC-24U-FS-SSS |
24VAC/DC |
AG2-NCAC-120-NF-SSS |
80950mA, SS Out., Nor. De-Ener. |
N.C. 1A@240VAC |
120VAC |
AG2-NCAC-24U-NF-SSS |
24VAC/DC |
AG2-NCDC-120-FS-SSS |
80950mA, SS Out., Nor. Ener. |
N.C. 0.15A@30VDC |
120VAC |
AG2-NCDC-24U-FS-SSS |
24VAC/DC |
AG2-NCDC-120-NF-SSS |
80950mA, SS Out., Nor. De-Ener. |
N.C. 0.15A@30VDC |
120VAC |
AG2-NCDC-24U-NF-SSS |
24VAC/DC |
AG2-NOAC-120-FS-SSS |
80950mA, SS Out., Nor. Ener. |
N.O. 1A@240VAC |
120VAC |
AG2-NOAC-24U-FS-SSS |
24VAC/DC |
AG2-NOAC-120-NF-SSS |
80950mA, SS Out., Nor. De-Ener. |
N.O. 1A@240VAC |
120VAC |
AG2-NOAC-24U-NF-SSS |
24VAC/DC |
AG2-NODC-120-FS-SSS |
80950mA, SS Out., Nor. Ener. |
N.O. 0.15A@30VDC |
120VAC |
AG2-NODC-24U-FS-SSS |
24VAC/DC |
AG2-NODC-120-NF-SSS |
80950mA, SS Out., Nor. De-Ener. |
N.O. 0.15A@30VDC |
120VAC |
AG2-NODC-24U-NF-SSS |
24VAC/DC |
AG3-NCAC-120-FS-TR3 |
5, 10, 30mA SS Out., Nor. Ener. |
N.C. 1A@240VAC |
120VAC |
Standard Items |
AG3-NCAC-24U-FS-TR3 |
5, 10, 30mA SS Out., Nor. Ener. |
N.C. 1A@240VAC |
24V AC/DC |
AG3-NCAC-120-NF-TR3 |
5, 10, 30mA SS Out., Nor. De-Ener. |
N.C. 1A@240VAC |
120VAC |
AG3-NCAC-24U-NF-TR3 |
5, 10, 30mA SS Out., Nor. De-Ener. |
N.C. 1A@240VAC |
24V AC/DC |
AG3-NCDC-120-FS-TR3 |
5, 10, 30mA SS Out., Nor. Ener. |
N.C. 0.15A@30VDC |
120VAC |
AG3-NCDC-24U-FS-TR3 |
5, 10, 30mA SS Out., Nor. Ener. |
N.C. 0.15A@30VDC |
24V AC/DC |
AG3-NCDC-120-NF-TR3 |
5, 10, 30mA SS Out., Nor. De-Ener. |
N.C. 0.15A@30VDC |
120VAC |
AG3-NCDC-24U-NF-TR3 |
5, 10, 30mA SS Out., Nor. De-Ener. |
N.C. 0.15A@30VDC |
24V AC/DC |
AG3-NOAC-120-FS-TR3 |
5, 10, 30mA SS Out., Nor. Ener. |
N.O. 1A@240VAC |
120VAC |
AG3-NOAC-24U-FS-TR3 |
5, 10, 30mA SS Out., Nor. Ener. |
N.O. 1A@240VAC |
24V AC/DC |
AG3-NOAC-120-NF-TR3 |
5, 10, 30mA SS Out., Nor. De-Ener. |
N.O. 1A@240VAC |
120VAC |
AG3-NOAC-24U-NF-TR3 |
5, 10, 30mA SS Out., Nor. De-Ener. |
N.O. 1A@240VAC |
24V AC/DC |
AG3-NODC-120-FS-TR3 |
5, 10, 30mA SS Out., Nor. Ener. |
N.O., 0.15A@30VDC |
120VAC |
AG3-NODC-24U-FS-TR3 |
5, 10, 30mA SS Out., Nor. Ener. |
N.O., 0.15A@30VDC |
24V AC/DC |
AG3-NODC-120-NF-TR3 |
5, 10, 30mA SS Out., Nor. De-Ener. |
N.O. 0.15A@30VDC |
120VAC |
AG3-NODC-24U-NF-TR3 |
5, 10, 30mA SS Out., Nor. De-Ener. |
N.O. 0.15A@30VDC |
24V AC/DC |
|
|