Back to NK
Technologies Main Selection Page |
AC and DC Current Switches |
AS1 Series, Single-Range AC Current Switch |
AS1 DODC
Series, Current Switch with Dual Output |
AS3 Series, Multi-Range AC Current Operated Switches |
ASM Series,
Self-Calibrating AC Current Switches |
ASX Series, AC Current Switches with Time Delay |
ASXP Series,
Powered AC Current Switches with Time Delay |
AS0 Series, Low Range AC Current Operated Switches |
DS3 Series, DC
Current Operated Switches |
AC and DC Current
Transducers |
AT Series, AC Current Transducers, Average Responding |
ATR Series, AC
Current Transducers, True RMS |
AT/ATR 3 & 4 Series, High Current AC Transducers |
ATP Series, Powered
AC Current Transducers |
ATP/ATPR 3 & 4 Series, Powered AC Current Transducers, True
RMS |
DT Series, DC Current
Transducers |
Ground Fault / Earth Leakage
Sensors |
AG Series, Ground Fault/Earth Leakage Sensors - Solid-State
Relay Output |
AG Series, Ground
Fault/Earth Leakage Sensors - Mechanical Relay Output |
AGL Series, Large Aperture Ground Fault
Sensors |
|
NK Technologies - AGL Series Large Aperture Ground Fault Sensors |
|
AGL Series, new from NK Technologies, is a large aperture ground fault sensor that offers one of the largest aperture diameters in the industry while maintaining a compact overall profile. Intended for sensing earth leakage in applications up to 600A, the AGL Series offers a choice of N.O. or N.C. latching relays or an SPDT Form C relay with auto-reset. Enclosure features integral DIN-rail mounting as standard and optional noise immunity coatings for applications in harsh EMI/RFI environments. |
|
Download Complete Specifications in .pdf Format |
- Replace bulky two-piece sensor solutions
which require separate CTs or relay modules.
- Use with shunt trip breakers to provide
total ground fault protection to sensitive machine electronics.
- Detect ground faults in
resistance/impedance heating, industrial automation and control, theatrical
lighting, portable power distribution, and snow melt/heat trace
applications.
- Sense progressive levels of ground fault in
motors or heating systems to detect deterioration prior to catastrophic
failure.
|
|
|
Features: |
- Integral DIN-rail Mount with Spring Loaded
Mounting Clips
- Setpoint Options Include Factory Adjustable
Setpoint from 5mA –100mA or “TR3 Tri-Set” Models with
Field-selectable 5/10/30mA Settings
- Finger-safe Terminals for Worry-free
Installation and Operation
- Aperture Orientation is Perpendicular to
DIN-rail, Allowing for Clean and Efficient Wiring and Minimizing Space Between
Multiple Components
- Choice of Dependable Latching SPST or SPDT
(Form C) Electromechanical Relay Outputs
- Uses “Zero Sum” Operating
Principle to Reliably Sense Imbalance in Magnetic Fields Associated with
Current Leakage to Ground
- Typical Response Times from 15ms to
200ms
- Integral “Push-to-test” Button
with LED Indication of Contact Status
|
|
|
|
Download Complete Specifications in .pdf Format |
Setpoint Range |
Factory calibrated models (specify when ordering): Factory calibrated models (specify when ordering):
- AGL1: 5–100mA (005–100)
- AGL2: 80–950mA (080–950)
|
TR3 Tri-set models (field jumper select): AGL3: 5, 10, or 30mA |
Output |
- Auto Reset: SPDT Relay 1A @ 125VAC, 2A @
30VDC
- Latching: SPST Relay 1A @ 125VAC, 2A @
30VDC
|
Response Time |
- 200ms @ 5% above trip point
- 60ms @ 50% above trip point
- 15ms @ 500% above trip point
|
Isolation Voltage |
5,000 VAC (tested) |
Frequency Range |
5060 Hz (monitored circuit) |
Noise Immunity Option |
- EMI/RFI Shielding
- Power supply noise filtering
|
Power Supply |
- 120VAC (55–110% of nominal voltage)
- 24VAC/VDC (+/- 10% of nominal voltage)
- Green LED = Power On indication
|
Case |
UL94 V0 Flammability Rated |
Environmental |
-4 to 122°F (-20 to 50°C), 095% RH, non-condensing |
|
|
|
Ordering Information |
Download Complete Specifications in .pdf Format |
Solid-Core Models Only |
Model |
Description |
Output |
Power Supply |
Notes |
AGL1-NCR1-120-LA-SSS |
5-100mA, Latching |
N.C. 1A@120VAC, 2A@30VDC |
120VAC |
Special Order Items - SSS is the Setpoint. Insert your desired setpoint 005 (5mA) through 100 (100mA) for the AGL1 models and 005 (5mA) through 950 (950mA) for the AGL2 models in the Special Shipping Instructions of your order.
Add an N at the end of any of the model numbers for the high-noise immunity option. Add $65.00 to the list price for this option. |
AGL1-NCR1-120-LA-SSSN |
AGL1-NOR1-120-LA-SSS |
5-100mA, Latching |
N.O. 1A@120VAC, 2A@30VDC |
120VAC |
AGL1-NOR1-120-LA-SSSN |
AGL1-SDT1-120-DEN-SSS |
5-100mA, Normally De-Energized |
SPDT 1A@120VAC, 2A@30VDC |
120VAC |
AGL1-SDT1-120-DEN-SSSN |
AGL1-SDT1-120-ENE-SSS |
5-100mA, Normally Energized |
SPDT 1A@ 20VAC, 2A@30VDC |
120VAC |
AGL1-SDT1-120-ENE-SSSN |
AGL1-NCR1-24U-LA-SSS |
5-100mA, Latching |
N.C. 1A@120VAC, 2A@30VDC |
24V AC/DC |
AGL1-NCR1-24U-LA-SSSN |
AGL1-NOR1-24U-LA-SSS |
5-100mA, Latching |
N.O. 1A@120VAC, 2A@30VDC |
24V AC/DC |
AGL1-NOR1-24U-LA-SSSN |
AGL1-SDT1-24U-DEN-SSS |
5-100mA, Normally De-Energized |
SPDT 1A@120VAC, 2A@30VDC |
24V AC/DC |
AGL1-SDT1-24U-DEN-SSSN |
AGL1-SDT1-24U-ENE-SSS |
5-100mA, Normally Energized |
SPDT 1A@ 20VAC, 2A@30VDC |
24V AC/DC |
AGL1-SDT1-24U-ENE-SSSN |
AGL2-NCR1-120-LA-SSS |
80-95 mA, Latching |
N.C. 1A@120VAC, 2A@30VDC |
120VAC |
AGL2-NCR1-120-LA-SSSN |
AGL2-NOR1-120-LA-SSS |
80-950mA, Latching |
N.O. 1A@120VAC, 2A@30VDC |
120VAC |
AGL2-NOR1-120-LA-SSSN |
AGL2-SDT1-120-DEN-SSS |
80-950mA, Normally De-Energized |
SPDT 1A@120VAC, 2A@30VD |
120VAC |
AGL2-SDT1-120-DEN-SSSN |
AGL2-SDT1-120-ENE-SSS |
80-950mA, Normally Energized |
SPDT 1A@120VAC, 2A@30VDC |
120VAC |
AGL2-SDT1-120-ENE-SSSN |
AGL2-NCR1-24U-LA-SSS |
80-950mA, Latching |
N.C. 1A@120VAC, 2A@30VDC |
24V AC/DC |
AGL2-NCR1-24U-LA-SSSN |
AGL2-NOR1-24U-LA-SSS |
80-950mA, Latching |
N.O. 1A@120VAC, 2A@30VDC |
24V AC/DC |
AGL2-NOR1-24U-LA-SSSN |
AGL2-SDT1-24U-DEN-SSS |
80-950mA, Normally De-Energized |
SPDT 1A@120VAC, 2A@30VDC |
24V AC/DC |
AGL2-SDT1-24U-DEN-SSSN |
AGL2-SDT1-24U-ENE-SSS |
80-950mA, Normally Energized |
SPDT 1A@ 20VAC, 2A@30VDC |
24V AC/DC |
AGL2-SDT1-24U-ENE-SSSN |
AGL3-NCR1-120-LA-TR3 |
5, 10, 30mA, Latching |
N.C. 1A@120VAC, 2A@30VDC |
120VAC |
Standard Items -
Add an N at the end of any of the model numbers for the high-noise immunity option. Add $65.00 to the list price for this option. |
AGL3-NCR1-120-LA-TR3N |
AGL3-NOR1-120-LA-TR3 |
5, 10, 30mA, Latching |
N.O. 1A@120VAC, 2A@30VDC |
120VAC |
AGL3-NOR1-120-LA-TR3N |
AGL3-SDT1-120-DEN-TR3 |
5, 10, 30mA, Normally De-Energized |
SPDT 1A@120VAC, 2A@30VDC |
120VAC |
AGL3-SDT1-120-DEN-TR3N |
AGL3-SDT1-120-ENE-TR3 |
5, 10, 30mA, Normally Energized |
SPDT 1A@120VAC, 2A@30VD |
120VAC |
AGL3-SDT1-120-ENE-TR3N |
AGL3-NCR1-24U-LA-TR3 |
5, 10, 30mA, Latching |
N.C. 1A@120VAC, 2A@30VDC |
24V AC/DC |
AGL3-NCR1-24U-LA-TR3N |
AGL3-NOR1-24U-LA-TR3 |
5, 10, 30mA, Latching |
N.O. 1A@120VAC, 2A@30VDC |
24V AC/DC |
AGL3-NOR1-24U-LA-TR3N |
AGL3-SDT1-24U-DEN-TR3 |
5, 10, 30mA, Normally De-Energized |
SPDT 1A@120VAC, 2A@30VDC |
24V AC/DC |
AGL3-SDT1-24U-DEN-TR3N |
AGL3-SDT1-24U-ENE-TR3 |
5, 10, 30mA, Normally Energized |
SPDT 1A@120VAC, 2A@30VDC |
24V AC/DC |
AGL3-SDT1-24U-ENE-TR3N |
|
|