Back to NK
Technologies Main Selection Page |
AC and DC Current Switches |
AS1 Series, Single-Range AC Current Switch |
AS1 DODC
Series, Current Switch with Dual Output |
AS3 Series, Multi-Range AC Current Operated Switches |
ASM Series,
Self-Calibrating AC Current Switches |
ASX Series, AC Current Switches with Time Delay |
ASXP Series,
Powered AC Current Switches with Time Delay |
AS0 Series, Low Range AC Current Operated Switches |
DS3 Series, DC
Current Operated Switches |
AC and DC Current
Transducers |
AT Series, AC Current Transducers, Average Responding |
ATR Series, AC
Current Transducers, True RMS |
AT/ATR 3 & 4 Series, High Current AC Transducers |
ATP Series, Powered
AC Current Transducers |
ATP/ATPR 3 & 4 Series, Powered AC Current Transducers, True
RMS |
DT Series, DC Current
Transducers |
Ground Fault / Earth Leakage
Sensors |
AG Series, Ground Fault/Earth Leakage Sensors - Solid-State
Relay Output |
AG Series, Ground
Fault/Earth Leakage Sensors - Mechanical Relay Output |
AGL Series, Large Aperture Ground Fault
Sensors |
|
AT Series, AC Current Transducers, Average Responding |
|
AT Series Current Transducers combine a current transformer and signal conditioner into a single package. The AT Series has jumper selected current input ranges and industry standard 420mA, 05VDC or 010VDC outputs. The AT Series is designed for application on linear or sinusoidal AC loads. Available in a split-core case or two types of solid-core cases. |
|
Download Complete Specifications in .pdf Format |
Automation Systems Analog current reading for remote monitoring and software alarms. |
Data Loggers Self-powered transducer helps conserve data logger batteries. |
Panel Meters Simple connection displays power consumption. |
|
- Accurate - Factory matched and calibrated
single piece transducer is more accurate than traditional two-piece field
installed solutions.
- Average Responding - “Average
Responding” algorithm gives an RMS output on pure sine waves. Perfect for
constant speed (linear) loads.
- Jumper Selectable Ranges
- Reduces inventory.
- Eliminates zero and span pots.
- Isolation
- Output is magnetically isolated from
the input for safety.
- Eliminates insertion loss (voltage
drop).
- UL, CUL and CE Approval - Accepted worldwide.
|
|
|
|
|
-005 Model |
-010 Model |
-420 Model |
Output Signal |
05VDC |
010VDC |
420mA |
Output Limit |
8.2VDC |
15VDC |
32mA |
Accuracy |
1.0% FS |
1.0% FS |
1.0% FS |
Response Time (1090% step change) |
100 ms |
100 ms |
300ms |
Frequency Range |
5060Hz |
5060Hz |
20100Hz |
Other Frequencies |
Special calibration available for any frequency from 10400Hz |
Power Supply |
Self-powered |
Self-powered |
1240VDC, Loop-powered |
Loading |
1mOhm min. for rated accuracy 100K.. add 1.3% error |
See Power Supply below |
Isolation Voltage |
UL listed to 1,270VAC (tested to 5KV) |
Input Ranges |
Field selectable ranges from 0200A; custom ranges available; consult factory. |
Sensing Aperture |
- -FF Case: 0.55” (14mm) dia.
- -FT Case: 0.74” (19mm) dia.
- -SP Case: 0.85” (21.6mm) sq.
|
Case |
UL94 V0 Flammability Rated |
Environmental |
-4 to 122°F (-20 to 50°C) 095% RH, noncondensing |
Listings |
UL 508 Industrial Control Equipment (USA & Canada), CE |
*Forsinusoidalwaveformsonly.SelectATRTransducersfordistortedwaveforms.. |
|
|
|
Ordering Information |
Download Complete Specifications in .pdf Format |
Solid-Core Models |
Model |
Description |
Output |
AT0-420-24L-FF |
02 & 05A Ranges, Front Term. |
420mA |
AT0-420-24L-FT |
02 & 05A Ranges, Top Term. |
420mA |
AT1-005-000-FF |
010, 020 & 050A Ranges, Front Term. |
05VDC |
AT1-005-000-FT |
010, 020 & 050A Ranges, Top Term. |
05VDC |
AT1-010-000-FF |
010, 020 & 050A Ranges, Front Term. |
010VDC |
AT1-010-000-FT |
010, 020 & 050A Ranges, Top Term. |
010VDC |
AT1-420-24L-FF |
010, 020, 050A Ranges, Front Term. |
420mA |
AT1-420-24L-FT |
010, 020, 050A Ranges, Top Term. |
420mA |
AT2-005-000-FF |
0100, 0150 & 0200A Ranges, Front Term. |
05VDC |
AT2-005-000-FT |
0100, 0150 & 0200A Ranges, Top Term. |
05VDC |
AT2-010-000-FF |
0100, 0150 & 0200A Ranges, Front Term. |
010VDC |
AT2-010-000-FT |
0100, 0150 & 0200A Ranges, Top Term. |
010VDC |
AT2-420-24L-FF |
0100, 0150, 0200A Ranges, Front Term. |
420mA |
AT2-420-24L-FT |
0100, 0150, 0200A Ranges, Top Term. |
420mA |
Split-Core Models |
Model |
Description |
Output |
AT0-420-24L-SP |
02 & 05A Ranges |
420mA |
AT1-005-000-SP |
010, 020 & 050A Ranges |
05VDC |
AT1-010-000-SP |
010, 020 & 050A Ranges |
010VDC |
AT1-420-24L-SP |
010, 020, 050A Ranges |
420mA |
AT2-005-000-SP |
0100, 0150 & 0200A Ranges |
05VDC |
AT2-010-000-SP |
0100, 0150 & 0200A Ranges |
010VDC |
AT2-420-24L-SP |
0100, 0150, 0200A Ranges |
420mA |
|
|