Wago Main Page |
I/O Products |
|
Fieldbus Coupler |
Programmable Feildbus Controller |
Digital Input Modules |
Digital Output Modules |
|
1 Channel |
230V AC, 16A, relay 1a |
2 Channel |
24V DC,
0.5A |
24V DC, 2.0A |
24V DC,
0.5A, diagnostics |
24V DC,
2.0A, diagnostics |
24V DC,
EEx i |
125V AC,
0.5A, relay 2 CO contacts, pot. free |
230V AC,
1.0A relay 2 CO contacts, pot. free |
230V AC,
0.3A, solid state relay |
230V AC,
3.0A, solid state relay for 30s |
230V AC,
2.0A, relay 2 NO |
230V AC,
2.0A, relay 2 NO, pot. free |
4 Channel |
5V DC, 20
mA |
24V DC,
0.5A |
24V DC,
0.5A, 2-conductor |
24V DC,
0.5A, low-side switching |
8 Channel |
24V DC,
0.5A |
|
|
Analog Input Modules |
Analog Output Modules |
Specialty Modules |
System Modules |
Approvals |
|
Wago Digital Output Modules |
|
Part Number |
Conformity Marking |
Approvals |
750-512 |
|
cULus, ABS, BV, DNV, GL, LR, RINA, KEMA |
2-CHANNEL RELAY OUTPUT MODULE RELAY 2 NO NON-FLOATING CARRIER RAIL DIN 35 CAGE CLAMP CONNECTION |
The connected load is switched via the digital output (relay contacts) from the control system. The internal system voltage is used to trigger the relays. Note that the power jumper contacts supply both N (common point) and switched output voltages (this may be DC or AC). The switched status of the relay outputs is shown by a LED. The module is a 2-channel, 4-conductor device and actuators with a ground (earth) wire may be directly connected to the module. Attention: An additional supply module must be added for the supply of AC 250 V/ DC 30 V! |
|
Technical Information |
Characteristic |
Value |
Number of outputs |
2 MAKE CONTACTS |
Current consumption max (internal) |
100 mA |
Switching voltage |
AC 250 V / DC 30 V |
Switching power |
500 VA / 60 W (resistive load) cos j max. =0.4; L/R max = 7 ms |
Switching current (max) |
AC / DC 2 A |
Switching current (min) |
AC/DC 10mA / 5V |
Max. switching frequency |
30 / MIN (AT NOMINAL LOAD) |
Pull-in time max. |
10 ms |
Drop-out time max. |
10 ms |
Bounce time typ (ms) |
1.2 ms |
Contact material |
SILVER ALLOY |
Mechanical life |
2 x 10^7switching operations |
Electrical life |
3x10^5 SWITCHING OPERATIONS (AC 2 A / 250 V) OR (DC 2 A / 30 V) |
Isolation |
1.5 kV EFF. (FIELD/SYSTEM), 2.5 kV RATED SURGE VOLTAGE; OVERVOLTAGE CATEGORY III |
Internal data width (Bit) |
2 Bit |
Operating temperature |
0 °C ... + 55 °C |
Storage temperature |
-25 °C ... +85 °C |
Relative air humidity |
95% |
Vibration resistance |
acc. IEC 60068-2-6 |
Shock resistance |
acc. IEC 60068-2-27 |
Degree of protection |
IP 20 |
EMC immunity to interference |
acc. EN 50082-2 (96) |
|
Characteristic |
Value |
EMC emission of interference |
per EN 50081-1 (93) |
UL 508 |
E175199, UL 508 |
EMC marine applications - noise proof |
gem. Germanischer Lloyd (1997) |
KEMA |
01ATEX1024X Eex nA II T4 |
EMC marine applications - noise transmission |
gem. Germanischer Lloyd (1997) |
Conformity marking |
CE |
Cross section from [mm²] |
0.08 mm² |
Cross section to [mm²] |
2.5 mm² |
Cross section from [AWG] |
28 AWG |
Cross section to [AWG] |
14 AWG |
Voltage CSA |
230 V |
Current rating CSA |
2:00 AM |
Weight |
54.5 g |
Color |
light gray |
Height |
64 mm |
Height |
2.52 in |
Width |
12 mm |
Width |
0.472 in |
Depth |
100 mm |
Depth |
3.937 in |
Strip length from |
8 mm |
Strip length to |
9 mm |
Strip length |
0.33 in |
|
|
|