Wago Main Page |
I/O Products |
|
Fieldbus Coupler |
Programmable Feildbus Controller |
Digital Input Modules |
Digital Output Modules |
|
1 Channel |
230V AC, 16A, relay 1a |
2 Channel |
24V DC,
0.5A |
24V DC, 2.0A |
24V DC,
0.5A, diagnostics |
24V DC,
2.0A, diagnostics |
24V DC,
EEx i |
125V AC,
0.5A, relay 2 CO contacts, pot. free |
230V AC,
1.0A relay 2 CO contacts, pot. free |
230V AC,
0.3A, solid state relay |
230V AC,
3.0A, solid state relay for 30s |
230V AC,
2.0A, relay 2 NO |
230V AC,
2.0A, relay 2 NO, pot. free |
4 Channel |
5V DC, 20
mA |
24V DC,
0.5A |
24V DC,
0.5A, 2-conductor |
24V DC,
0.5A, low-side switching |
8 Channel |
24V DC,
0.5A |
|
|
Analog Input Modules |
Analog Output Modules |
Specialty Modules |
System Modules |
Approvals |
|
Wago Digital Output Modules |
|
Part Number |
Conformity Marking |
Approvals |
750-507 |
|
cULus, cULus-EX KEMA |
2-CHANNEL ANALOG OUTPUT MODULE DC 24 V POSITIVE SWITCHING SHORT-CIRCUIT PROTECTED CARRIER RAIL DIN 35 |
The connected load is switched via the digital output from the control system. All outputs are electronically short-circuit-protected. In addition to the functions that can be fulfilled by the standard output modules, these output modules can recognize a short circuit or an open circuit. The error is visually indicated by error LEDs and a bit is set in the process image. The module is a 2-channel, 4-conductor device and actuators with ground (earth) wire may be directly connected to the module. Each output is electrically isolated from the bus by use of optocouplers. |
|
Technical Information |
Characteristic |
Value |
No. of outputs |
2 |
CURRENT CONSUMPTION (INTERNAL) mA |
15 mA |
Voltage via power jumper contacts (max) |
DC 24 V (-15% / + 20%) |
Type of load |
resistive, inductive, lamps |
Max. switching frequency (kHz) |
2.5 kHz |
Reverse voltage protection |
Yes |
Output current max. (A) |
2:00 AM |
Short-circuit range typ. Pwm |
33 A (42 A peak) |
Open-circuit detection |
< 60 ?A |
Diagnostics |
Open circuit-, overload- and short-circuit protection |
Power consumption max. |
1.7 J |
Isolation |
500 V system / supply |
Current consumption typ (field side) |
15 mA / MODULE + LOAD |
Internal data width |
2 Bit In, 2 Bit Out |
Operating temperature |
0 °C ... + 55 °C |
Storage temperature |
-25 °C ... +85 °C |
Relative air humidity |
95% |
Vibration resistance |
acc. IEC 60068-2-6 |
Shock resistance |
acc. IEC 60068-2-27 |
Degree of protection |
IP 20 |
|
Characteristic |
Value |
EMC immunity to interference |
acc. EN 50082-2 (96) |
EMC emission of interference |
per EN 50081-1 (93) |
UL 508 |
E175199, UL 508 |
UL 1604 |
E198726, UL 1604 Class 1 Dev2 ABCD T4A |
KEMA |
01ATEX1024X Eex nA II T4 |
Conformity marking |
CE |
Cross section from [mm²] |
0.08 mm² |
Cross section to [mm²] |
2.5 mm² |
Cross section from [AWG] |
28 AWG |
Cross section to [AWG] |
14 AWG |
Voltage CSA |
24 V |
Current rating CSA |
2:00 AM |
Weight |
52.5 g |
Color |
light gray |
Height |
64 mm |
Height |
2.52 in |
Width |
12 mm |
Width |
0.472 in |
Depth |
100 mm |
Depth |
3.937 in |
Strip length from |
8 mm |
Strip length to |
9 mm |
Strip length |
0.33 in |
|
|
|