Wago Analog Input Modules |
|
Part Number |
Conformity Marking |
Approvals |
750-485 |
|
TÜV (EEx i) |
Only use this modue lin connection with the 24V DC EEx i supply module (
750-625 ) |
2-CHANNEL ANALOG INPUT MOUDLE 4-20 mA |
The analog input module provides the power to the intrinsically safe transducers located in the hazardous area of Zone 1 and process their analog signals. WAGO-I/O-SYSTEM 750 has to be installed in Zone 2 or in non-hazardous environments. The 24V supply is derived from the power jumper contacts. The transmitter supply is non-inherently electronically short-circuit-protected. The shield (screen) is directly connected to the DIN rail. Indicators: Green LED (signal on/off) Red LED (wire breakage, measuring range overflow/ underflow) Each input is electrically isolated from the bus by use of optocouplers. Note:Only use the digital input module in connection with the 24V DC EEx i supply module
750-625 . |
|
Power Supply Instructions |
When operating the intrinsically safe EEx i modules in connection with sensors/ actuators operating in hazardous environments of Zones 0 and 1, the supply module 24V DCEEx i (
750-625 ) must be used to supply the I/O modules.
Note: If further 24V DC EEx i supply modules are required, four separation modules (
750-616 ) must be placed between the intrinsically safe sections. |
|
Technical Information |
Characteristic |
Value |
No. of inputs |
2 |
Voltage via power jumper contacts (max) |
SUPPLY VIA DC 24.7 V EEX I SUPPLY MODULE
750-625 |
Current consumption typ (internal) |
31 mA |
Transmitter supply |
Uv = 16 V bei 20 mA |
Signal current |
4 - 20 mA |
Input resistance |
< 100 Ohm |
Resolution (Bit) |
12 Bit |
Conversion time (typ) |
2 ms |
Measuring error (25°) |
< +/- 0.2 % of the full scale value |
Temperature coefficient |
< +/- 0.01 % / K of the full scale value |
Power consumption P max. (W) |
1.3 W |
Heat dissipation |
0.75 W |
Input current typ. (field side) |
11 mA + load |
Isolation |
375 V System / Supply |
Data size |
2 x 16 Bit Data2 x 8 Bit control / status (optional) |
Ex guideline |
94 / 9 / EG |
Marking |
Ex II 3 (1) G [EEx ia] IIC/IIB |
Safety data |
U0 = 27,3 V ; I0 = 93 mA |
Intrinsically safe / EEx ib IIB / EEx ib IIC |
L0 / 18 mH / 5 mH |
Intrinsically safe / EEx ib IIB / EEx ib IIC |
C0 / 680 nF / 88 nF |
EC EMC standards |
89 / 336 / EWG |
|
Characteristic |
Value |
EC low voltage standards |
73 / 23 / EWG |
Operating temperature |
0 °C ... + 55 °C |
Storage temperature |
-25 °C ... +85 °C |
Relative air humidity |
95% |
Vibration resistance |
acc. IEC 60068-2-6 |
Shock resistance |
acc. IEC 60068-2-27 |
Degree of protection |
IP 20 |
EMC immunity to interference |
gem. EN 61000-6-2 (1999) |
EMC emission of interference |
gem. EN 61000-6-4 (2002) |
Cross section from [mm²] |
0.08 mm² |
Cross section to [mm²] |
2.5 mm² |
Cross section from [AWG] |
28 AWG |
Cross section to [AWG] |
14 AWG |
Weight |
48.5 g |
Color |
blue |
Height |
64 mm |
Height |
2.52 in |
Width |
24 mm |
Width |
0.945 in |
Depth |
100 mm |
Depth |
3.937 in |
Strip length from |
8 mm |
Strip length to |
9 mm |
Strip length |
0.33 in |
|
|