Wago Specialty Modules |
|
Part Number |
Conformity Marking |
Approvals |
750-635 |
|
cULus, cULus-EX, KEMA |
DIGITAL IMPULSE INTERFACE CARRIER RAIL DIN 35 |
The digital impulse interface is designed for the connection of magnetostrictive distance measurement sensors with a start/stop interface. After receiving a read pulse, these sensors deliver a time-delayed reply impulse. The time delay is proportional to the sensor distance. Each sensor may have up to four position transmitters (permanent magnets). Their position data can be accessed serially by the control. The position data is stored in the process image of the fieldbus coupler as a 24 bit value. The parameterization of the ultrasonic speed and the transmission points is done via the control byte. The parameters can be changed during operation. The transmission of the impulses is done with RS 422 differential drivers which guarantees trouble free data transmission. Distance sensors with the following features can be used: Start/Stop interface with RS 422 differential signals, Sensor supply 24 V, Manufacturer: e.g. Balluff |
|
Technical Information |
Characteristic |
Value |
Transmitter connection |
Start / Stop; Init; Uv; ground shield via the housingof the sensor |
No. of inputs |
1 |
CURRENT CONSUMPTION (INTERNAL) mA |
45 mA |
Voltage via power jumper contacts (max) |
DC 24 V (-15% / + 20%) |
Data transmission |
RS 422 |
Signal output |
Differential signal (RS 422) |
Signal input |
Differential signal (RS 422) |
Resolution (?m) |
1 ?m |
HYSTERESIS, PRECISION |
depends on the distance sensor |
Precision |
depends on the distance sensor |
Update time |
2 ms |
Distance sensor length |
<= 4 m |
Line length (max) |
500 m |
Isolation |
500 V system / supply |
Data size |
1 x 24 Bit Data1 x 8 Bit Control / status |
Operating temperature |
0 °C ... + 55 °C |
Storage temperature |
-25 °C ... +85 °C |
Relative air humidity |
95% |
Vibration resistance |
acc. IEC 60068-2-6 |
|
Characteristic |
Value |
Shock resistance |
acc. IEC 60068-2-27 |
Degree of protection |
IP 20 |
EMC immunity to interference |
acc. EN 50082-2 (96) |
EMC emission of interference |
per EN 50081-1 (93) |
UL 508 |
E175199, UL 508 (applied for) |
Conformity marking |
CE |
Cross section from [mm²] |
0.08 mm² |
Cross section to [mm²] |
2.5 mm² |
Cross section from [AWG] |
28 AWG |
Cross section to [AWG] |
14 AWG |
Weight |
51 g |
Color |
light gray |
Height |
64 mm |
Height |
2.52 in |
Width |
12 mm |
Width |
0.472 in |
Depth |
100 mm |
Depth |
3.937 in |
Strip length from |
8 mm |
Strip length to |
9 mm |
Strip length |
0.33 in |
|
|