Connex-Electronics.com
Qualtek Products
Open Frame Switching Power Supplies - QPS-60 (60 Watts - Single Output)

Open Frame Switching Power Supplies - QPS-60 (60 Watts - Single Output)
   
Features:
  • Universal AC input/ Full range
  • Wide Operating Ambient Temperature (-25°C~70°C)
  • High Efficiency, low power consumption
  • Output Protections: OLP/OVP/SCP
  • All using 105°C long life electrolytic capacitors.
  • 100% full load burn-in test
Qualtek QPS-60
 
Approvals
 
Click here for specification and dimensions in .pdf formatPDF
Part Number Add part number QPS-60-5 to your Quote. QPS-60-5 Add part number QPS-60-12 to your Quote. QPS-60-12 Add part number QPS-60-15 to your Quote. QPS-60-15 Add part number QPS-60-24 to your Quote. QPS-60-24 Add part number QPS-60-48 to your Quote. QPS-60-48
Output Charateristics
DC Output 5V 12V 15V 24V 48V
Rated Current 8A 4.5A 3.6A 2.5A 1.25A
Current Range 0~8A 0~4.5A 0~3.6A 0~2.5A 0~1.25A
Ripple and Noise 0~70°C <50mV <120mV <120mV <120mV <240mV
-25~0°C <200mV <300mV <300mV <300mV <360mV
Voltage Adj. Range 4.5~5.5V 11.2V~13.4V 13.8V~16.5V 22.2V~27.9V 45.0V~53.2V
Voltage Accuracy ±3% ±3% ±3% ±3% ±3%
Line Regulation ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
Load Regulation ±2% ±2% ±2% ±2% ±2%
Set-up Time less than or equal to 1.0s (230VAC input, full load)
Hold-up Time greter than or equal to 20ms (230VAC input, full load)
Temperature Coefficient ±0.03% / °C
Overshoot and Undershoot <5.0%
Input Characteristics
Voltage Range 90VAC~264VAC, 127-370VDC
Frequency Range 47Hz-63Hz
Efficiency (Typical) 115VAC Input 79% 83% 84% 87% 85%
230VAC Input 82% 85% 85% 87% 88%
AC Current (max) <1.5A
Inrush Current (Typical) 30A@115VAC Cold start; 60A@230VAC Cold Start
Leakage Current <0.25mA
Protection
Over Load (OLP) 105%~180% of rated output current, hiccup mode, auto recovery
Over Voltage (OVP) 110%~150% of rated output voltage, constant voltage
Short Circuit (SCP) Long-term mode, auto recovery
Environmental Characteristics
Operating Amb. Temp and Hum. -25°C~70°C, 20%~90% RH Non-Condensing
Storage Temp. and Hum. -40°C~85°C: 10%-95% RH Non-Condensing
Safety Standards UL60950-1; EN60950-1: 2006
Withstand Voltage Primary-Secondary: 3.0KVAC; < or =10mA.
Isolation Resistance > or = 100M ohms
EMI Conduction and Radiation Compliance to EN55022(CISPR22) Class B
Harmonic Current Compliance to EN61000-3-2, -3
EMS Immunity Compliance to EN61000-4-2, 3, 4, 5, 6, 8, 11; ENV50204, light industry level, criteria A
General Charaterisitcs
MTBF (MIL-HDBK-217F) More than 200,000 Hrs (25°C, Full load)
Dimensions (LxWxH) 101.6 x 50.8 x 30 mm
Packing 60 PCS/CTN. G.W: 12kgs
Cooling Method Cooling by free air convection