Features:
- Universal AC input/ Full range
- High Efficiency, and High Reliability
- Output Protections: OLP/OVP/SCP
- Wide operating ambient temperature
(-25°C~70°C)
- All using 105°C long life electrolytic
capacitors.
- 100% full load burn-in test
|
|
|
|
Part Number |
QPD-60-5 |
QPD-60-12 |
QPD-60-15 |
QPD-60-24 |
QPD-60-48 |
Output Charateristics |
DC Output |
5V |
12V |
15V |
24V |
48V |
Rated Current |
10A |
5A |
4A |
2.5A |
1.25A |
Current Range |
0~10A |
0~5A |
0~4A |
0~2.5A |
0~1.25A |
Ripple and Noise
(-20~70°C) |
<50mV |
<50mV |
<100mV |
<100mV |
<200mV |
Voltage Adj. Range |
4.6V-5.5V |
11.0V-13.0V |
13.7V-16.0V |
22.0V-25.3V |
45.3V-51.3V |
Voltage Accuracy |
±2% |
±2% |
±2% |
±2% |
±2% |
Line Regulation |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
Load Regulation |
±2% |
±2% |
±2% |
±2% |
±2% |
Set-up Time |
<2.0s (115VAC input, full
load); <1.0s (230VAC input, full load) |
Hold-up Time |
>10ms (115VAC input, full
load); >20ms (230VAC input, full load) |
Temperature Coefficient |
±0.03% / °C |
Overshoot and Undershoot |
<5.0% |
Input Characteristics |
Voltage Range |
88VAC~264VAC, 124-370VDC |
Frequency Range |
47Hz-63Hz |
Efficiency (Typical) |
115VAC Input |
75% |
81% |
81% |
83% |
84% |
230VAC Input |
76% |
82% |
82% |
83% |
85% |
AC Current (max) |
1.5A |
Inrush Current (Typical) |
<40A@115VAC Cold start; <60
A@230VAC Cold Start |
Leakage Current |
<0.25mA@115VAC;
<3.5mA@230VAC |
Protection |
Over Load (OLP) |
105%~150% of rated output current,
hiccup mode, auto recovery |
Over Voltage (OVP) |
120%~150% of rated output voltage,
shut down, re-power on to recover (5V) 110%~133% of rated output voltage,
shut down, re-power on to recover (12V) 110%~140% of rated output voltage,
shut down, re-power on to recover (15V, 24V) 110%~125% of rated output
voltage, shut down, re-power on to recover (48V) |
Short Circuit (SCP) |
Long-term mode, auto recovery |
Environmental
Characteristics |
Operating Amb. Temp and
Hum. |
-20°C~70°C, 20%~90% RH
Non-Condensing |
Storage Temp. and Hum. |
-40°C~85°C: 10%-95% RH
Non-Condensing |
Safety Standards |
UL60950-1; EN60950-1: 2006 |
Withstand Voltage |
Primary-Secondary: 3.0KVAC; less
than or equal to 10mA. Primary-PG: 1.5KVAC; less than or equal to 10mA.
Secondary-PG: 0.5KVDC; less than or equal to 10mA |
Isolation Resistance |
greater than or equal to 100M
ohms |
EMI Conduction and
Radiation |
Compliance to EN55022(CISPR22)
Class B |
Harmonic Current |
Compliance to EN61000-3-2, -3 |
EMS Immunity |
Compliance to EN6100-4-2, 3, 4, 5,
6, 8, 11; ENV50204, light industry level, criteria A |
General Charaterisitcs |
MTBF (MIL-HDBK-217F) |
More than 200,000 Hrs (25°C,
Full load) |
Dimensions (LxWxH) |
129 x 98 x 38 mm |
Packing |
30 PCS/CTN. G.W: 14.2kgs |
Cooling Method |
Cooling by free air
convection |