Connex-Electronics.com
Qualtek Products
Enclosed Frame Switching Power Supplies - QPD-60 (60 Watts - Single Output)

Enclosed Frame Switching Power Supplies - QPD-60 (60 Watts - Single Output)
   
Features:
  • Universal AC input/ Full range
  • High Efficiency, and High Reliability
  • Output Protections: OLP/OVP/SCP
  • Wide operating ambient temperature (-25°C~70°C)
  • All using 105°C long life electrolytic capacitors.
  • 100% full load burn-in test
Qualtek QPD-60
 
Approvals
 
Click here for specification and dimensions in .pdf formatPDF
Part Number Add part number QPD-60-5 to your Quote. QPD-60-5 Add part number QPD-60-12 to your Quote. QPD-60-12 Add part number QPD-60-15 to your Quote. QPD-60-15 Add part number QPD-60-24 to your Quote. QPD-60-24 Add part number QPD-60-48 to your Quote. QPD-60-48
Output Charateristics
DC Output 5V 12V 15V 24V 48V
Rated Current 10A 5A 4A 2.5A 1.25A
Current Range 0~10A 0~5A 0~4A 0~2.5A 0~1.25A
Ripple and Noise (-20~70°C) <50mV <50mV <100mV <100mV <200mV
Voltage Adj. Range 4.6V-5.5V 11.0V-13.0V 13.7V-16.0V 22.0V-25.3V 45.3V-51.3V
Voltage Accuracy ±2% ±2% ±2% ±2% ±2%
Line Regulation ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
Load Regulation ±2% ±2% ±2% ±2% ±2%
Set-up Time <2.0s (115VAC input, full load); <1.0s (230VAC input, full load)
Hold-up Time >10ms (115VAC input, full load); >20ms (230VAC input, full load)
Temperature Coefficient ±0.03% / °C
Overshoot and Undershoot <5.0%
Input Characteristics
Voltage Range 88VAC~264VAC, 124-370VDC
Frequency Range 47Hz-63Hz
Efficiency (Typical) 115VAC Input 75% 81% 81% 83% 84%
230VAC Input 76% 82% 82% 83% 85%
AC Current (max) 1.5A
Inrush Current (Typical) <40A@115VAC Cold start; <60 A@230VAC Cold Start
Leakage Current <0.25mA@115VAC; <3.5mA@230VAC
Protection
Over Load (OLP) 105%~150% of rated output current, hiccup mode, auto recovery
Over Voltage (OVP) 120%~150% of rated output voltage, shut down, re-power on to recover (5V)
110%~133% of rated output voltage, shut down, re-power on to recover (12V)
110%~140% of rated output voltage, shut down, re-power on to recover (15V, 24V)
110%~125% of rated output voltage, shut down, re-power on to recover (48V)
Short Circuit (SCP) Long-term mode, auto recovery
Environmental Characteristics
Operating Amb. Temp and Hum. -20°C~70°C, 20%~90% RH Non-Condensing
Storage Temp. and Hum. -40°C~85°C: 10%-95% RH Non-Condensing
Safety Standards UL60950-1; EN60950-1: 2006
Withstand Voltage Primary-Secondary: 3.0KVAC; less than or equal to 10mA.
Primary-PG: 1.5KVAC; less than or equal to 10mA.
Secondary-PG: 0.5KVDC; less than or equal to 10mA
Isolation Resistance greater than or equal to 100M ohms
EMI Conduction and Radiation Compliance to EN55022(CISPR22) Class B
Harmonic Current Compliance to EN61000-3-2, -3
EMS Immunity Compliance to EN6100-4-2, 3, 4, 5, 6, 8, 11;
ENV50204, light industry level, criteria A
General Charaterisitcs
MTBF (MIL-HDBK-217F) More than 200,000 Hrs (25°C, Full load)
Dimensions (LxWxH) 129 x 98 x 38 mm
Packing 30 PCS/CTN. G.W: 14.2kgs
Cooling Method Cooling by free air convection