Connex-Electronics.com
Qualtek Products
Enclosed Frame Power Supplies with Power Factor Correction - QPDF-100 (100 Watts - Single Output)

Enclosed Frame Power Supplies with Power Factor Correction - QPDF-100 (100 Watts - Single Output)
   
Features:
  • Universal AC input/ Full range
  • Built-in active PFC function, PF>0.95
  • High Efficiency, and High Reliability
  • Output Protections: OLP/OVP/SCP
  • All using 105°C long life electrolytic capacitors.
  • 100% full load burn-in test
Qualtek QPDF-100
 
Approvals
 
Click here for specification and dimensions in .pdf formatPDF
Part Number Add part number QPDF-100-5 to your Quote. QPDF-100-5 Add part number QPDF-100-12 to your Quote. QPDF-100-12 Add part number QPDF-100-15 to your Quote. QPDF-100-15 Add part number QPDF-100-24 to your Quote. QPDF-100-24 Add part number QPDF-100-36 to your Quote. QPDF-100-36 Add part number QPDF-100-48 to your Quote. QPDF-100-48
Output Charateristics
DC Output 5V 12V 15V 24V 36V 48V
Rated Current 20A 8.5A 6.7A 4.2A 2.75A 2.10A
Current Range 0~20A 0~8.5A 0~6.7A 0~4.2A 0~2.75A 0~2.10A
Ripple and Noise 0~60°C <50mV <100mV <100mV <100mV <100mV <100mV
-10~0°C <100mV <100mV <100mV <100mV <100mV <100mV
Voltage Adj. Range 4.5V~5.5V 10.6V~13.6V 13.5V~17.0V 21.8V~27.4V 32.6V~39.9V 44V~52V
Voltage Accuracy ±2% ±2% ±2% ±1% ±1% ±1%
Line Regulation ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
Load Regulation ±1% ±1% ±1% ±1% ±1% ±1%
Set-up Time <4.0s (115VAC input, full load); <2.0s (230VAC input, full load)
Hold-up Time >10ms (115VAC input, full load); >20ms (230VAC input, full load)
Temperature Coefficient ±0.03% / °C
Overshoot and Undershoot <5.0%
Input Characteristics
Voltage Range 90VAC~264VAC, 127-370VDC
Frequency Range 47Hz-63Hz
Efficiency (Typical) 115VAC Input 78% 84% 84% 84% 84% 86%
230VAC Input 80% 86% 86% 86% 86% 87%
AC Current (max) <1.7A
Inrush Current (Typical) 30A@115VAC Cold start; 50 A@230VAC Cold Start
Leakage Current Input-Output: <0.25mA Input-PG: <3.5mA
Protection
Over Load (OLP) 105%~150% of rated output current, hiccup mode, auto recovery
Over Voltage (OVP) 110%~150% of rated output voltage, shut down, re-power on to recover
Short Circuit (SCP) Long-term mode, auto recovery
Environmental Characteristics
Operating Amb. Temp and Hum. -10°C~60°C, 20%~90% RH Non-Condensing
Storage Temp. and Hum. -20°C~85°C: 10%-95% RH Non-Condensing
Safety Standards UL60950-1; EN60950-1: 2006
Withstand Voltage Primary-Secondary: 3.0KVAC; <=10mA.
Primary-PG: 1.5KVAC;<=10mA.
Secondary-PG: 0.5KVDC;<=10mA
Isolation Resistance >=100M ohms
EMI Conduction and Radiation Compliance to EN55022(CISPR22) Class B
Harmonic Current Compliance to EN61000-3-2, 17625.1-2003
EMS Immunity Compliance to EN61000-4-2, 3, 4, 5, 6, 8, 11;
ENV50204, light industry level, criteria A
General Charaterisitcs
MTBF (MIL-HDBK-217F) More than 200,000 Hrs (25°C, Full load)
Dimensions (LxWxH) 194 x 99 x 50 mm
Packing 10 PCS/CTN. G.W: 8.1kgs
Cooling Method Cooling by free air convection