Wago Programmable Fieldbus Controller |
|
Part Number |
Standard |
Conformity Marking |
Approvals |
750-804 |
EN 50254 |
|
cULus, cULus-EX, KEMA |
INTERBUS PROGRAMMABLE FIELDBUS CONTROLLER DIGITAL AND ANALOG SIGNALS CAGE CLAMP CONNECTION |
The programmable fieldbus controller for INTERBUS is an expansion of the WAGO-I/O-SYSTEM. This controller combines the WAGO fieldbus coupler for INTERBUS with the functionality of a PLC. Programming of the application is done with WAGO-I/O-PRO 32 in accordance with IEC 61131-3, covering all 5 programming languages. The programmer can access all fieldbus and I/O data. Characteristics and use: l The use of decentralized control can better support a PLC or PC l Signal pre-processing reduces fieldbus transmissions l Complex applications can be divided into multiple tasks l Tasks can be prioritized l Peripheral equipment can be controlled directly, resulting in faster system response times l Programmable response in the event of a fieldbus failure l Simple, self-sufficient control |
|
Technical Information |
Characteristic |
Value |
Max. no. of nodes |
256 |
Max. no. Of I/O points |
4096 (depends on Master) |
Transmission medium |
certified Cu cable |
Max. length of fieldbus segment |
400 m |
Data transmission rate (kBaud) |
500 kBaud |
Transmission time |
typ. 1.43 ms (10 Stat; 32 dig. In- and output) |
Buscoupler connection |
1 x D-SUB 9; plug for input interface 1 x D-SUB 9; socket for output interface |
Programming |
WAGO-I/O-PRO 32 |
IEC 61131-3 |
AWL, KOP, PUP, ST, AS |
UL 508 |
E175199, UL 508 |
Standard |
EN 50254 |
Conformity marking |
CE |
Max. no. of I/O modules |
64 |
Max. fieldbus input image (Byte) |
64 Byte |
Max. fieldbus output image (Byte) |
64 Byte |
Input variables |
64 Byte |
Output variables |
64 Byte |
Configuration |
automatic |
Program memory |
128 kByte |
Data memory |
64 kByte |
Non-volatile memory (retain) |
8 kByte |
Cycle time |
< 3 ms for 1000 statements / 256 dig. I/Os |
Voltage supply |
DC 24 V (-15% / + 20%) |
Input current (max) |
500 mA |
Efficiency of the power supply |
87% |
|
Characteristic |
Value |
Internal current consumption |
400 mA |
Total current for the I/O modules |
1600 mA |
Isolation |
500 V system / supply |
Voltage via power jumper contacts (max) |
DC 24 V (-15% / + 20%) |
Current via power jumper contacts (max) |
DC 10 A |
Operating temperature |
0 °C ... + 55 °C |
Storage temperature |
-25 °C ... +85 °C |
Relative air humidity |
95% |
Vibration resistance |
acc. IEC 60068-2-6 |
Shock resistance |
acc. IEC 60068-2-27 |
Degree of protection |
IP 20 |
EMC immunity to interference |
acc. EN 50082-2 (96) |
EMC emission of interference |
acc. EN 50081-2 (94) |
Cross section from [mm²] |
0.08 mm² |
Cross section to [mm²] |
2.5 mm² |
Cross section from [AWG] |
28 AWG |
Cross section to [AWG] |
14 AWG |
Weight |
200 g |
Color |
light gray |
Height |
65 mm |
Height |
2.56 in |
Width |
51 mm |
Width |
2.008 in |
Depth |
100 mm |
Depth |
3.937 in |
Strip length from |
8 mm |
Strip length to |
9 mm |
Strip length |
0.33 in |
|
|