SAI-4-FMM-4P M12 5M |
Representative Photo |
|
Technical Information |
|
|
|
Application/Enclosure Requirements |
General Industrial Environment (Sensor distributors & Access.)
|
Bus Active System or Passive Application |
Passive
|
No. of Contact Pins |
4
|
Application Suggestion |
High Heat, High Impact Area, non-shielded
|
Homerun Cable Connection Method |
Fixed Cable, 5M
|
Cable Gland Diameter |
Does not apply
|
Cable Length |
Does not apply
|
No. of contact sockets |
4
|
Connector diameter |
M12
|
Additional Data |
|
|
|
Enclosure Material
| Zn
|
Max. voltage |
30 V
|
Protection Class |
IP 68/NEMA 6P
|
Height |
43 mm (1.69 inches)
|
Width |
60 mm (2.36 inches)
|
Length |
102 mm (4.02 inches)
|
Current per signal |
2 A
|
Total Current-Single Supply |
4.5 A
|
Total Current-Dual Supply |
|
min. voltage |
10 Veff
|
Rated Voltage |
32 Veff
|
Test voltage |
1 kVeff
|
Degree of soiling |
3
|
Insulation Resistance |
> 10^9 MOhm
|
Plugging cycles |
<= 50
|
Conductor O.D., min |
10 mm (0.39 inches)
|
Conductor O.D., max. |
14 mm (0.55 inches)
|
Contact Material |
CuZn
|
Contact carrier material |
Pocan
|
Contact tube O-ring material |
Viton
|
Hood sealing material |
PUR foamed
|
Flammability Class |
V0
|
LED color for operation function |
green
|
Electrical isolation via jumpering available |
no
|
Operation temperature, min. |
-20 °C
|
Operation temperature, max. |
90 °C
|
Storage temperature, min. |
-20 °C
|
Storage temperatur, max. |
90 °C
|
Suggested Accessories |
|
|