Power-Sonic Model PS-12120 Sealed Lead-Acid Battery
|
Order Part Number:
PS-12120
General
Specifications |
Dimensions: |
Length |
5.95 inches |
151 millimeters |
Width |
3.86 inches |
98 millimeters |
Height |
3.70 inches |
94 millimeters |
Height over Terminals |
3.94 inches |
100 millimeters |
Approximate Weight |
9.00 pounds |
4.10 kilograms |
Terminals: |
Quick disconnect tabs
(0.250" x 0.032") |
Case: |
ABS Plastic |
Electrical
Specifications |
Nominal Voltage: |
12 Volts (6 cell in series)
|
Nominal Capacity:
|
20 hour rate |
(600mA to 10.50 volts) |
12.0 AH |
10 hour rate |
(1100mA to 10.50 volts) |
11.0 AH |
5 hour rate |
(2000mA to 10.20 volts) |
10.0 AH |
1 hour rate |
(7800mA to 9.00 volts) |
7.80 AH |
Energy Density (20 hour rate)
|
1.69 Watt-hours/cubic inch |
103.6 Watt-hours/l |
Specific Energy (20 hour rate)
|
16.4 Watt-hours/pound |
35.1 Watt-hours/kg |
Internal Resistance (Fully Charged
Battery) |
16 milliohms (approx.)
|
|
Charging :
Cycle Applications: Limit initial current to 2400mA. Charge
until battery voltage (under charge) reaches 14.40 to 14.70 volts at 68º F
(20º C). Hold at 14.40 to 14.70 volts until current drops to approximately
120mA. Battery is fully charged under these conditions, and charger should
either be disconnected or switched to "float" voltage.
"Float" or "Stand-by
Service": Hold battery across constant voltage source of 13.50 to 13.80
volts continuously. When held at this voltage, the battery will seek its own
current level and maintain itself in a fully charged condition.
|